• After the sterilisation process, three bars are shown on the display. This shows that from this
point onwards, the items in the sealed steriliser will remain sterile for up to three hours. The
passage of time is displayed in hourly steps from III to I. After the final hour has passed, 0 is
shown on the display.
• After three hours have passed, the items must be newly sterilised, regardless of whether or
not the device was opened.
• Use the sterilised parts immediately after removal, or else they will require re-sterilising.

8. Cleaning and maintenance

The service life of the device depends on careful use:
• Use distilled water for the sterilisation.
• Unplug the device before cleaning.
• To clean the device, use only a damp cloth. Do not use any scouring agents or other cleaning
products.
• Descale the device using vinegar or citric acid. Descale the device with vinegar or citric acid. Mix 50
ml white vinegar with 100 ml cold water or a packet of citric acid with 200 ml cold water and pour
the solution into the device. Leave the solution to work until the lime scale has been removed; do not
operate the device during this time. Pour the liquid away, rinse the device out thoroughly and finally dry
it with a cloth.
• Descale the device approx. every four weeks.

9. Disposal

For environmental reasons, do not dispose of the device in the household waste at the end of its useful life.
Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accordance
with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions,
please contact the local authorities responsible for waste disposal.

10. Technical data

Supply voltage:
Output:

11. What if there are problems?

Fault
The device does not switch on
after the cable is plugged in.
The device switches itself off after
the warming up phase, there are
no more displays.
The device switches itself off
midway through the process, and
there are no more displays.
No LED display
12
220 - 240 V ~ / 50/60 Hz
500 watts
Cause
No electricity
No water in the
steriliser
Too little water in the
steriliser
Mains plug not (prop-
erly) plugged in or
faulty device
Action
Check that the plug is properly
plugged in.
Unplug the device, allow it to cool
down, then fill it with 120 ml water
and start the programme as de-
scribed in the instructions.
Check that the mains plug is (prop-
erly) plugged in. If there is still no
display, switch the device off, unplug
it and return the device to the retailer.