Technical Data - Profi Care PC-IPL 3024 Manual De Instrucciones

Sistema de eliminación de vello
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Problem
It will not emit a light flash when
the release button is pressed.
Smoke can be seen or smelled
during operation.
The indicator lamp START
and one of the level displays
remain lit.
The indicator lamp START is lit.
And the other indicator lamps
start flashing.

Technical Data

Model:................................................................. PC-IPL 3024
Power supply:...................................................DC 12 V, 2,5 A
Light surface: ............................................................... 2.7 cm
Technology used: ..........................IPL (Intense Pulsed Light)
Flash duration: ..................................................500 to 800 µs
Intensity density: .........................................................4J / cm
Wavelength: ...................................................475 to 1200 nm
Net weight: ....................................................... approx. 0.4 kg
Temperature:
Operation: ................................................+10 °C to +35 °C
Storage: ................................................... -40 °C to +70 °C
92
PC-IPL3024_IM
Possible Cause
The attachment is not properly
placed on the appliance.
The appliance is not yet
operational.
Poor contact with the skin.
The lamp in the attachment is
defective.
The appliance is faulty.
Immediately stop the usage!
System error
The appliance has reached the
end of its life.
Relative air humidity:
Atmospheric pressure:
2
External Power Adapter
2
Input: ............................AC 100 − 240 V, 50 / 60 Hz, 0,8 A Max
Output:.................................................................DC 12 V / 3 A
Polarity: ......................................................................
Protection class:: ...................................................................
The right to make technical and design modifications in the
course of continuous product development remains reserved.
Solution
Ensure that the attachment has been mounted
correctly.
Makes sure that the indicator lamp START flashes
green.
Ensure that the skin support contact fully rests on
the skin.
Replace the attachment with a new one.
If the error persists, contact our customer service.
Contact our service centre or a specialist.
Switch the appliance off. Disconnect the power
adapter from the socket for around 5 seconds. Re-
insert the power adapter into the socket and switch
the appliance back on.
If the error persists, contact our customer service.
Dispose the appliance properly. See chapter
"Disposal".
Operation: ....................................................3 % to 75 % rH
Storage: .....................................................10 % to 90 % rH
Operation: .................................................700 to 1060 hPa
Storage: ....................................................500 to 1060 hPa