Installation Guide
Installer setup
Setup functions
0383
Over-cooling limit
0384
Dehumidification
fan action
SOUTHERN DEHUMIDIFICATION AWAY SETTINGS
0390
Away mode
0391
Away mode
fan setting
0392
Away mode low
limit temp.
0393
Away mode temp.
setting
0394
Away dehumidifi-
cation setting
0400
Ventilation control
0401
Number of
bedrooms
0402
Size of house
0403
Ventilation level
0404
Max. ventilation
% limit
0405
Ventilation fan
action
0406
Ventilation in high
humidity
0500
Furnace filter
change alert
(English: Page 4 • Français: Page 10 • Español: Página 16)
Settings & Options
3 3°F (1.5°C)
[Other options: 1, 2 (1°F or 2°F/0.5°C to 1.5°C)]
0 System fan turns on with dehumidifier
1 Dehumidifier operates independent of fan
0 No
1 Yes
0 Fan auto
1 Fan always on
2 Fan circulate
76 Low limit temperature 76°F (24°C)
[Other options: 70°F to 80°F (21°C to 27°C)]
85 Away temperature 85°F (29°C)
[Other options: 70°F to 99°F (21°C to 37°C)]
65 Away humidity level 65%
[Other options: 55% to 70%]
0 No ventilation
1 Ventilation always allowed
2 Ventilation not allowed during sleep period
2 Two bedrooms
[Other options: 1 to 6]
10 1,000 square feet
[Other options: 11 to 50 (1,100 to 5,000 square feet]
160 CFM (cubic feet per minute)
[Other options: (30 to 195 CFM)]
50 50% ventilation limit
[Other options: 30% to 60%]
P Meets ASHRAE 62.2 standard
F Does not meet ASHRAE 62.2 standard
1 Ventilation on forces fan on
2 Ventilation does not force fan on
1 On (heat mode only)
0 Off
E Auto Discover
0 Off
1 10-day run time
2 30-day run time
3 60-day run time
4 90-day run time
5 120-day run time
6 180-day run time
(factory default in bold)
**
7 270-day run time
8 365-day run time
9 30 calendar days
10 60 calendar days
11 90 calendar days
12 120 calendar days
13 180 calendar days
14 365 calendar days
6
** See page 8