Description; Components; Indoor Station; Roadside Panel - Extel WEPA 401 LC SER.R1 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14

2. DESCRIPTION

(fig. 1)
1 •
Power supply
2 •
Handset
3 •

Roadside panel

Introduction
This interphone consists of an interior response unit and an exterior street plate with which communications can
be established with the visitor who has rung.
For proper use, please read this notice thoroughly and keep the Instruction Manual.

3. COMPONENTS

(fig. 2)
a. Indoor station
(fig. 2-a)
1. Loudspeaker for speaking.
2. Microphone for communication with the street plate.
3. Control of a strike or electrical lock or gate mechanism command
4. Outlet for the 15 V
plug of the adapter (adapter to connect to an installation compliant with NCF 15-100
standards in force in France).
5. Terminal block to connect the wires
b. Roadside panel
(fig. 2-b)
1. Speaker: allows to be heard outside.
2. Call button, when pressing this button, the internal unit rings,
3. The microphone allows you to communicate with the internal unit.
4. Terminal block to connect the wires
5. Setting of the sound level for the speaker of the roadside panel.

4. INSTALLING

N.B. :
If you try your product before installation, do not do so with the street plate and the response unit in the
same room. Otherwise, the interphone will emit a piercing tone (the Larsen effect).
Before the installation :
Assembly procedure of the nameplate (fig.3)
1. Write your name on the label.
2. Place carefully the block in its original position.(the label and the nameplate)
a. Installing of the roadside panel
(fig. 4)
1. Fit the plastic box taking (1) care not to block the attachment nuts of the panel.
2. Remove the 2 screw caps (2) with a small screwdriver to put in the slot (3).
3. Connect the link wire according to the wiring diagram. (fig. 6)
4. Fix the board on the built-in box sing the two screw (4) supplied ; do not forget the waterproof gasket (6).
5. Replace the 2 screw caps.
Important :
Put a silicon gasket on the upper half between the external panel and the wall (5).