TROUBLE SHOOTING
If the dehumidifier is used according to this manual, you should enjoy trouble free use. In cases of difficulty please check the
following points before contacting your reseller.
Symptom
The dehumidifier does not
start
Water is leaking outside the
water container
Reduced water extraction
Not collecting water
The dehumidifier produces a
strange noise
TECHNICAL DATA
Model
Mains
Power consumption
at 27 °C, 60% RH
Heater
to save energy the heater switches off at 25 °C
Water extraction
at 30 °C, 70% RH
at 32 °C, 90% RH
Water container capacity
Refrigerating agent
Airflow
Operating temperature (min - max)
Dimensions
length
height
depth
Wheel diameter
Weight
gross / net
Meets EEC directive 73/23/CE (LVD).
Check
Is the POWER light on?
Is the WATER CONTAINER FULL
light on?
Is HUMIDISTAT set to a high relative
humidity?
Has the unit been running in cold
temperatures under 5 °C?
Has the water container been
removed for emptying straight
after the unit was running?
Is HUMIDISTAT set to a high
relative humidity?
Are the filters blocked?
Is the air already relatively dry?
Is the unit running in a cold room?
Generally the colder the air, the
less moisture will be removed.
Is the WATER CONTAINER FULL
light on?
Is HUMIDISTAT set to a high
relative humidity?
Check whether the unit is placed
on a level surface.
W
W
L/24h
L
m 3 /h
°C
mm
mm
kg
Solution
Make sure the unit is plugged into a live mains socket.
Check the fuse in the plug and if necessary replace with
another fuse.
Make sure the water container is empty and fitted properly
in position.
Select a lower humidity setting or continuous running
mode.
Only run the unit in a heated space above 5 °C.
Wait a few minutes to allow condensation within the unit
to flow into the container after switching off the unit and
before removing the container.
Select a lower humidity setting or continuous running
mode.
Washable air filter may need cleaning. Activated carbon
filter may need cleaning/replacing.
Select a lower humidity setting or continuous running
mode. Extraction is reduced when the humidity level is
lower.
Ensure that the unit is operating in a heated space above
5 °C.
Make sure the water container is empty and fitted properly
in position.
Select a lower humidity setting or continuous running
mode.
The unit should be placed on a level surface.
idealday 18
idealday 18H
230 V - 50 Hz
380
380
-
800
15
15
18
18
7
R134a
160
5 - 35
345
722
325
120
22.0 / 19.5
Specifications may change without prior notice.