SALINITY Salinity is displayed along with the gpl (grams per liter) indicator, when the SALINITY
button (C) is depressed. If a reading of HH appears, the salinity is above 4.5 to 6.5
gpl (depending on pool temperature) and is too high to measure correctly (at normal
temperatures). Maintain salinity between 3.0 and 3.5 gpl. See Section 4.
ADD SALT The ADD SALT indicator comes on when the fl ow/temp/salinity sensor determines that the
salinity level of the pool water is too low. Maintain Salinity between 3.0 and 3.5 gpl.
SERVICE and
The SERVICE indicator will turn on whenever the control system detects a problem that
Service Code
requires attention. The SERVICE indicator is accompanied by a service code displayed on
the front panel, displayed as a three (3) digit code. The service code(s) are displayed twice
per minute with an audible alarm.
NOTE See Section 7.2, Service Codes. Problems can range from insuffi cient salinity to the DC cord not connected.
Audible Alarm An audible alarm (beep) sounds once per hour, and only for the fi rst service code, when
a SERVICE condition is detected. The alarm can be cleared by pressing and holding the
SALINITY button (C) for fi ve (5) seconds. The audible alarm can be cleared for 24 hours
or until the power to the unit is turned off and back on whichever comes fi rst. However, the
audible alarm will return if a new problem is detected.
NOTE The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center
power interface board.
Audible Alarm
Audible alarm operation and volume control can be adjusted. To adjust volume control,
Volume Control
press and hold the TEMPERATURE button (D) for 15 seconds. The system will beep once
when pressed, once after 10 seconds and once after 15 seconds. Release the key after the
third beep. Press the SALINITY button (C) within fi ve (5) seconds to enter the temperature
change screen.
NOTE The boost cycle is normally activated after 10 seconds, however, if the key is held
The system will display a '1' followed by 'F' or 'C'. Press the TEMPERATURE button
(D) to move to the second parameter screen. The screen will display a 0, and the alarm
volume will be fully reduced. The system will occasionally show a '2' to display the screen
number. Press the arrow button B to increase the volume and the arrow button A to reduce
the volume. The volume increments from 0 to 100 in 20 steps. After each press of the arrow
buttons, the alarm will activate to demonstrate the current volume level. When the alarm
volume has been adjusted to the desired setting, press the SALINITY button (C) to confi rm
the new alarm volume setting. The change will be stored in permanent memory. If you do
not wish to keep the change, wait fi ve (5) seconds, and the change screen will 'time out' and
return to normal operation without keeping any changes to the system. Any changes made
to the alarm volume will NOT be saved if this occurs.
Nature
Fusion Soft Installation and Operation Manual
down until after the third beep at 15 seconds, the Boost mode will not be changed.