Problem
Power Indicator
will not illuminate
(blue)
Ionization
Indicator is
flashing (green)
Ionization
Indicator is
flashing (green)
while the display
reads '00'
Low copper level
High copper level
8
Possible Cause
No power to the
control panel
Controller failure
Debris lodged between
the electrodes
The electrodes are not
immersed in water
Control panel cannot
detect a connection the
electrode
Electrodes are depleted
Level of ionization set
too low
Copper ions are quickly
consumed
Level of ionization set
too high
1-877-80-PONDS
www.atlanticwatergardens.com
Possible Solution
Inspect the 110 volt GFCI outlet/12
volt AC transformer power outlet
Contact Dealer for repair/replacement
Remove the electrodes by rotating
½ turn in a counter clockwise direction.
Inspect the electrodes and remove
any debris
Check the water flow through the
electrode housing and verify that the
housing is full of water
Inspect the quick-connect plug on the
Electrode and verify that the line to the
control panel is not damaged
Remove the electrodes by rotating
½ turn in a counter clockwise direction.
Inspect the electrodes and verify that
replacement is needed. Install a new
TRION2-RA replacement electrode.
Increase the level of ionization and
monitor copper levels
It is not unusual for the test strips to
show low copper levels after long
periods of operating at "full" power.
This is due to copper ions being
consumed within the water feature as
they break down organics.
Reduce ionization to '01' on the
display until test results are below
0.3 ppm. A partial water change will
also aid in reducing copper levels