1
Safety Notes
1.1
Intended use
Universally deployable for the cleaning of all pipes with a Ø 20 - 50 mm pipe diameter. This de-
vice may only be used in accordance with the regulations as stated. Other applications are not
permissible!
1.2
General Power Tool Safety Warnings
WARNING! Read all safety instructions, other instructions, illustrations and
technical data associated with the driving tool.
1.3
Special safety instructions
The equipment must only be operated by qualified specialized staff!!
When using a power-driven driving tool the electrical installation must be checked at the work-
place before commissioning the pipe cleaning device.
Only use a suitable driving tool with electronic speed regulation as indicated in the technical da-
ta.
Never use the locking button on the On/Off switch of the driving tool!
Observe the reaction torque of the driving tool on the spiral drum and only work with both hands.
Hold the pipe cleaning device firmly at the driving tool and control grip!
Start the driving tool at a low speed!
Set a low torque level on the driving tool if present!
Never touch the rotating spiral!
Never allow the spiral to rotate outside of the pipe!
Watch out for the distance between the pipe cleaning device and the pipe opening! The distance
should not exceed 20 cm.
Use a camera system if necessary to spot the cause of the pipe blockage cause.
1.4
Residual risks
Even when observing all of the safety instructions there are still some residual risks remaining,
for example: spirals can overturn (create a loop if the operating arc is too large) thereby creating
the risk of clamping. Spirals under tension can spring out of the pipe ~ a risk of injury!
2
Technical Data
Requirements on the driving tool ................. Drill chuck span 13 mm
Max. permissible speed ................................ 6 00 rpm clockwise rotation
Spiral rod diameter ...............................................................
Max. spiral rod length ...........................................................
Weight (for 7.5 m spirals) ............................. about 3.9 kg
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 62841-1.
Vibration total value ..............................................................
The Vibration Total Value quoted in these instructions and the quoted noise emission values
were measured according to standardized measurement procedures and can be used to com-
pare one electric power tool with another. They can also be used to make an initial estimate of
the loading.
8
) ............................ 71 dB (A) ¦ K
pA
) .............................. 82 dB (A) ¦ K
WA
ENGLISH
Torque a minimum of 30 Nm (soft)
Ø 8 mm
7,5 m
3 dB (A)
pA
3 dB (A)
WA
2
≤ 2,5 m/s
¦ K= 1,5m/s
2