Advanced Operation - Furman F1500-UPS Manual Del Propietário

Ocultar thumbs Ver también para F1500-UPS:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

F1500-UPS OWNER'S MANUAL
Display Brightness
Display Brightness adjusts the brightness of the display backlight.
Display Scroll Mode
If enabled, the display will automatically advance to the next screen every 5 or 10 seconds.
Display Sleep Mode
With Display Sleep Mode enabled, the display will go to the lowest brightness setting (25%) after the designated time of inactivity of
the Navigation Dial {30 SEC, 60 SEC }. The display will return to the set brightness level upon entering Setup Mode, or UPS Mode.
Automatic Regulation Setup
Setup for Automatic Voltage Regulation parameters.
Outlet Bank 3 Setup
Adjusts the battery charge threshold in which Outlet Bank 3 is shut off to conserve power for the critical loads connected to Outlet
Bank 1 & 2. If set to OFF, Outlet Bank 3 will shut off immediately when the unit goes into UPS Mode.
Outlet Bank 4 Setup
Adjusts the battery charge threshold in which Outlet Bank 4 is shut off to conserve power for the critical loads connected to Outlet
Bank 1 & 2. If set to OFF, Outlet Bank 4 will shut off immediately when the unit goes into UPS Mode.
External Battery
If using the external battery, BAT1500-EXT, set to YES.
IR1 Control Setup
IR1 Control Setup is a two-step process in which the IR1 remote control signal is sampled, and tested by outputting the learned
signal on the output jack (See advanced operation section for set-up details).
IR2 Control Setup
IR2 Control Setup is a two-step process in which the IR2 remote control signal is sampled, and tested by outputting the learned
signal on the output jack (See advanced operation section for set-up details).
IR Output Delay
IR Output Delay is the time delay before outputting the IR signals from the IR output jacks after the unit goes into UPS mode.
IR Output Delay time starts at 0 sec, incremented in 5 sec intervals, with a maximum value of 60 sec.
Setup Buzzer Mode
Change the UPS BUZZER MODE to set it to on or off.
UPS Test Mode
UPS Test Mode places the unit in UPS Mode temporarily to verify that the UPS inverter can adequately supply the connected load.
System Info
Displays the brand, model number and firmware revision.

ADVANCED OPERATION

A connection to a UPS can benefit projector bulbs, server based products, and units with volatile electronic memories found in but
not limited to Pro Audio, Broadcast, and High-End Home Theater equipment. The F1500-UPS takes this to the next level with a num-
ber of features designed specifically for AC Power back-up applications.
Critical Load Function
One of the user programmable settings in the F1500-UPS software is the Low Battery Non-Critical Load (NCL) Shutoff threshold.
This sets the battery capacity level at the point where the NCL outlets are turned off and all remaining battery power is reserved
for equipment plugged into the 4 critical load outlets. This value is stored internally by the UPS and is not dependent on having the
software running on a computer.
Patent-pending Learning IR Control
The learning IR function lets you program the F1500-UPS to send standby or shut-down commands to components such as DLP
ceiling projectors. If the power fails, the projector's lamps are turned off while the F1500-UPS continues providing battery power to
the projector's cooling fan. Proper shutdown is ensured and expensive lamps are protected from damage.
NOTE: This function should only be used with discrete IR codes. Programming an On/Off toggle command could result in the
equipment being turned ON during a power failure!
10

Publicidad

Tabla de contenido
loading

Productos relacionados para Furman F1500-UPS

Tabla de contenido