Standalone System
1. Description
The Standalone system requires non software and no management equipment to operate with it.
2. Shadow Programming Cards
3. Modes: Standard and Passage
Standard Users and PINs will access the door but they will not have the property to leave the door in passage mode.
Passage Mode means that no credential is required to open the door
4. ADD Standard Users: CANNOT change to Passage Mode
All processes described below have to be done in each door where a USER CARD or PIN will access.
Important: Shadow Function does not apply for user PINs although, a user PIN can be added in the locking plan.
1.
Approach the programming card once so the escutcheon changes into programming mode.
2.
Approach the user cards and its shadow card
Note: If a user is not paired with its shadow, it will not open the door (red light immediately).
Instructions v5.0 – P-E04000_A_N. Shadow Progamming Cards
Escutcheon, Wall Readers and Knob Cylinders are
compatible with this system
Furthermore they can also be found in all technologies:
Mifare: Using this technology, DESFire and
Mifare Cards can be used as User Card
ISO 15693 and compatible with Skidata, this
means that User Cards can use this cards
iCLASS®
Programming cards with shadow function allows adding user
cards and their shadows so both cards are paired. Only user
cards should be used in the installation to enter the door. The
shadow is created to cancel user cards in those cases where
the user card is lost.
Important: Only one programming card is attended in an
installation to be used in all devices. This is for all devices to
have the same system code.
Up to 500 user cards can be added in a device.
Up to 100 user PINs can be added in a device.
Standalone System