TMO-T-AU
TMO-T-AU-IAQ
LEGENDA
MC1 = Morsettiera controllo scheda
MC2 = Morsettiera alimentazione scheda
MC3 = Connettore sonda di minima
MFC = Morsettiera Fan-Coil
TME = Sonda di minima (optional)
M =
Motoventilatore
F =
Scheda filtro elettronico o resistenza elettrica
E1 =
Elettrovalvola acqua calda e fredda ( per impianto a 2 tubi )
E1 =
Elettrovalvola acqua calda ( per impianto a 4 tubi )
E2 =
Elettrovalvola acqua fredda ( per impianto a 4 tubi )
CH =
Cambio stagionale remoto (Estate-Inverno) (Collegamento ester-
no a cura dell'installatore)
LEGEND
MC1 = Control board terminal board
MC2 = Power board terminal board
MC3 = Low temperature cut-out thermostat connector
MFC = Fan coil terminal board
TME = Minimum sensor (optional)
M =
Motor-driven fan
F =
Electronic filter or electrical resistor board
E1 =
Hot and cold water solenoid valve (For 2-tube installations)
E1 =
Hot water solenoid valve (For 4-tube installations)
E2 =
Cold water solenoid valve(For 4-tube installations)
CH =
Remote season changeover (summer/winter) (external connection
responsibility of the installe
r)
14
LEGENDE
MC1 = Klemmenbrett Platinenkontrolle
MC2 = Klemmenbrett Platinenversorgung
MC3 = Wasser-thermostat Verbinder
MFC = Fan-Coil Klemmleiste
TME = Mindestsonde (Option)
M =
Motorlüfter
F =
Elektronische Filterplatine oder Heizwiderstand
E1 =
Elektroventil Warm- und Kaltwasser (Für 2-Leiter-Systeme)
E1 =
Elektroventil Warmwasser ( Für 4-Leiter-Systeme )
E2 =
Elektroventil Kaltwasser ( Für 4-Leiter-Systeme)
CH =
Fern-Saisonumschaltung (Sommer-Winter) (externer Anschluss
vom Installateur zu erstellen)
LÉGENDE
MC1 = Bornier contrôle carte
MC2 = Bornier alimentation carte
MC3 = Connecteur sonde d'eau
MFC = Bornier Fan-Coil
TME = sonde de température minimale (en option)
M =
Motoventilateur
F =
Carte filtre électronique ou résistance électrique
E1 =
Electro-vanne eau chaude et froide ( Pour installations à 2 tubes)
E1 =
Electro-vanne eau chaude (Pour installations à 4 tubes)
E2 =
Electro-vanne eau froide (Pour installations à 4 tubes)
CH =
Changement Eté-Hiver à distance (connexion extérieure effectuée
par l'installateur)
LEYENDA
MC1 = Terminal de conexión control tarjeta
MC2 = Terminal de conexión alimentación tarjeta
MC3 = Conector sonda de minima
MFC = Caja de bornes Fan-Coil
TME = Sonda de temperatura mínima (opcional)
M =
Motoventilador
F =
Ficha filtro electrónico o resistencia eléctrica
E1 =
Electroválvula agua caliente y fría (Para instalaciones de 2 tubos)
E1 =
Electroválvula agua caliente (Para instalaciones de 4 tubos)
E2 =
Electroválvula agua fría (Para instalaciones de 4 tubos)
CH =
Cambio estacional periódico (Verano - Invierno) (conexión externa
a cargo del instalador)
LEGENDE
MC1 = Klemmenbord schakelschema
MC2 = Klemmenbord voeding
MC3 = Connector watersonde
MFC = Klemmenbord ventilator-convector
TME = Minimumsonde (optie)
M =
Motorventilator
F =
Schakeling elektronische filter of elektrische weerstand
E1 =
Elektromagnetische klep koud en warm water (Voor installaties
met 2 leidingen)
E1 =
Elektromagnetische klep warm water (Voor installaties met 4
leidingen)
E2 =
Elektromagnetische klep koud water (Voor installaties met 4
leidingen)
CH =
Seizoensomschakeling vanop afstand (Zomer-Winter) (externe
aansluiting uit te voeren door installateur)
15