II. Installation Guide
Warning!
Switch off mains supply before removing an existing room thermostat or installing this controller.
Caution!
The device must only be opened by a competent electrician and installed according to the
wiring diagram in the housing cover or this guide. The existing safety regulations must be
complied with.
Appropriate installation measures must be taken to achieve the requirements of protection
class II.
This electronic device which can be installed independently may only be used to control the
temperature in dry and enclosed rooms in a normal environment.
This electronic device conforms to EN 60730, it works according to operating principle 1C.

1. Applications

The electronic thermostat E200 can be used to control room temperature together with:
• Actuators of floor heating systems or radiators
• Oil and gas warm water heating
• Circulating pumps
• Heat pumps
• Electric radiators