D
Storage of constants/historical
GB
storage
F
I
Storage of a constant
E
You can store and recall a frequently used value e.g.
NL
height of a room. Measure the desired distance,
P
press and hold the
to confirm storage.
N
FIN
Recalling the constant
DK
Press this button once to recall the constant
S
and make it available for further calculations by
TR
pressing button
CZ
Historical storage
SK
Press this button twice and the previous 20
PL
results (measurements or calculated results) are
SLO
shown in reverse order.
HR
The
and
H
Press this button to use a result from the
GR
summary line for further calculations.
RUS
Pressing the
erases all the values in historical storage.
LV
EST
LT
ROK
CN
Appendix
button until the device beeps
.
buttons can be used for navigation.
and
buttons at the same time
Timer (self-triggering)
Press this button to set a 5-second time delay.
or
Press and hold down this button until the
desired time delay is reached (max. 60 seconds).
Once the key is released the remaining seconds until
measurement (e.g. 59, 58, 57...) are displayed in a
countdown. The last 5 seconds are counted down
with a beep. After the last beep the measurement is
taken and the value is displayed.
)
The timer can be used for all measurements.
Appendix
Message codes
All message codes are displayed with either
"Error". The following errors can be corrected:
Cause
156
Transverse tilt
greater than 10°
160
Main tilt direction,
angle too high
(> 45°)
204
Calculation error
14
or
Remedy
Hold the instrument
without any transverse
tilt
Measure angle up to
max. ± 45°
Repeat procedure
Makita LD100P