1 Safety summary & control device setting
17 SAFETY SUMMARY & CONTROL DEVICE SETTING
Protection:

This switch cut out the operation on the DHWT when the water temperature inside DHWT exceed 90ºC.
Cut-Out
Contactors
Current
Voltage
Coil Voltaje
Electric Power
Voltage
ø
Resistances whole fixing flare nut
Specific heat load
Material
Resistance cord
Sensor
DHWT sensor
18 GENERAL STANDARD FOR HYDRAULIC INSTALLATION
The safety valve unit will fitted at the sanitary water installa-
tion.
A pressure reducer must be placed in the DHWT installation.
The nominal pressure of the safety unit will be 8 bar.
When the main pressure is more than 6 bar a pressure redu-
cer should be installed.
The water discharge during heating (expansion) is normal.
The volume of this discharge can be up to 3% of the storage
tank's capacity.
The pressure regulator device must be working regularly, de-
pending on the quality of water, in order to remove the lime's
deposits and verify that it is not blockade.
A water leakage in the pressure protection device can exist.
The discharge pipe should be always open to the atmosphe-
re, free of frost and in continuous slope to the down side.
Dielectric bushes must be fitted at the input and output sani-
tary water and at the tank circuit connections.
Emptying the DHWT: Close the main inlet water valve and
open the relief valve of the security water group.
22
Model
Thermostat
Heating resistances
PMML0198A-rev.1 - 04/2011
Units
DHWT
Manual Reset
ºC
90
A
20 (AC1)
V
230V
V
207~253V
kW
2.5
V
230V
mm
8
"G
2 (brass)
W/cm
8
²
iNCOLLOY 825
Ni-Cr 80/20 ø 0.45mm
NTC 20k
Ref.
Main inlet water
DHWT inlet connection
Security valve and manual empty
Emptying connection
Check valve
Close valve
1
6
4
Name
2
5
3