Short description
The Truma time-switch
– ZUE, Art. no. 39890-00 and
– ZUE 2, Art. no. 39891-00 for
the heaters Trumatic E 1800,
E 2400, E 2800 and E 4000
(series 2, from year of manu-
facture 1989)
– ZUC 2, Art. no. 34042-01 for
the heaters Trumatic C 3402
and C 6002
allows a programming of
3 switch-on times within 7 days.
The operating time is programm-
able up to a maximum of
2 hours. Continuos daily repeats
are not possible.
This timer switch must not be
used in conjunction with
Trumatic C 3400/C 6000 heating
units, Series 1, up to year of
manufacture 06/97.
10
4
3
1
2
2
1
3
MODIMIDOFRSASO
5
6
7
8
9
1 = Actual time or switch-on time
2 = Operation
3 = Programme number
4 = Actual day or switch-on time
5 = Key time
6 = Key programme number
7 = Immediate switch-on
8 = Key backwards
9 = Key forwards
Operating
instructions
The heater can be switched on or
off at the control panel or timer. If
the heater is to be switched on at
the timer the operation switch on
the control panel must be „OFF".
Following a interruption of the
power supply (e.g. removing or
charching the battery), the time
on the display flashes. A pro-
gramming of the heater is only
possible after entering the
current time.
Immediate switch-on
of the heater
Independent of any programmed
time, the heater can be switched
on or off with the key
.