6 Transport and storage of cordless tools
Transport
CAUTION
Inadvertent starting during transport. Uncontrolled starting during transport may occur if the battery
is fitted, thereby resulting in damage to the tool.
▶ Always remove the battery before transporting the tool.
▶ Remove the battery.
▶ Transport the tool and batteries individually packaged.
▶ Never transport batteries in bulk form (loose, unprotected).
▶ Check the tool and batteries for damage before use after long periods of transport.
Storage
CAUTION
Inadvertent damage caused by defective battery. A leaking battery may damage the tool.
▶ Always remove the battery before storing the tool.
▶ Store the tool and batteries in a place that is as cool and dry as possible.
▶ Never store batteries in direct sunlight, on heating units or behind a window pane.
▶ Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶ Check the tool and batteries for damage before use after long periods of storage.
7 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
7.1 Troubleshooting
Trouble or fault
The power tool does not
work.
The power tool does not work
and one LED flashes.
The on/off button cannot be
pressed, i.e. the button is
locked.
LED 1 flashes
The battery runs down more
quickly than usual.
Printed: 08.06.2017 | Doc-Nr: PUB / 5356121 / 000 / 00
Possible cause
The battery is not fully inserted.
Low battery.
Electrical fault.
Low battery.
The battery is too hot or too cold.
The forward/reverse selector
switch is in the middle position.
Low battery.
The tool is overloaded (application
limits exceeded).
Very low ambient temperature.
Action to be taken
▶ Push the battery in until it
engages with an audible double
click.
▶ Change the battery and charge
the empty battery.
▶ Remove the battery from the
tool and contact Hilti Service.
▶ Change the battery and charge
the empty battery.
▶ Bring the battery to the recom-
mended operating temperature.
▶ Push the forward/reverse switch
to the left or right.
▶ Change the battery and charge
the empty battery.
▶ Pay attention to the power
and performance rating of the
product before using it, i.e
check its suitability for the job
on hand. See the "Technical
data" section.
▶ Allow the battery to warm up
slowly to room temperature.