Get-Function Listing - ViewSonic IFP9850-3 Guia Del Usuario

Ocultar thumbs Ver también para IFP9850-3:
Tabla de contenido

Publicidad

3. Set Time example
Time: 16:27:59
Send:
0x 38 30 31 73 57 48 31 36 0D ("H16")
Send:
0x 38 30 31 73 57 4D 32 37 0D ("M27")
Send:
0x 38 30 31 73 57 53 35 39 0D ("S59")

10.3.2 Get-Function Listing

The PC can interrogate the LFD for specific information. The Get-Function packet
format consists of 9 bytes which is similar to the Set-Function packet structure. Note
that the "Value" byte is always = 000
Get-Function description:
Length:
Total Byte of Message excluding "CR".
TV/DS ID
Identification for each of TV/DS (01~98; default is 01).
Command Type
Identify command type,
"g" (0x67h) : Get Command
"r" (0x72h) : Valid command Reply
"-" (0x2Dh) : Invalid command Reply
Command:
Function command code: One byte ASCII code.
Value[1~3]:
Three bytes ASCII that defines the value.
CR
0x0D
Get-Function format
Send: (Command Type="g")
Name Length
ID
Byte
1 Byte 2 Byte
Count
Bytes
1
2~3
order
Reply: (Command Type="r" or "-")
If the Command is valid, Command Type ="r"
Name Length
ID
Byte
1 Byte 2 Byte
Count
Bytes
1
2~3
order
Command
Command Value1 Value2 Value3
Type
1 Byte
1 Byte
4
5
Command
Command Value1 Value2 Value3
Type
1 Byte
1 Byte
4
5
82
1 Byte
1 Byte
1 Byte 1 Byte
6
7
8
1 Byte
1 Byte
1 Byte 1 Byte
6
7
8
CR
9
CR
9

Publicidad

Tabla de contenido
loading

Tabla de contenido