Signaling
AL 9
The combustion air flow has
INSUFF
dropped below a predefined
threshold
DRAFT
AL b
Occurs when the gearmotor
AUG TRIAC
runs continuously
ERROR
AWAITING
Occurs on relighting the insert
immediately after turning it off
COOL
Occurs when the air flow
AIR FLOW
meter is disconnected. The
METER
controller does not detect the
amount of combustion air and
FAILURE
does not shut down the insert
Occurs when the stove has
SERVICE
exceeded 1800 hours of
operation or 2000 Kg pellet,
DUE
since the previous servicing.
ALARMS - MESSAGES
Fault
- The combustion chamber is
dirty
- The fume duct is blocked
- The fire door is not closed
- The overpressure valves are
open-jammed
- The air flow meter is dirty or
faulty
- Incorrect parameters entered
- Faulty main board
Insert still too hot to start a
lighting phase
The air flow meter connection
cable has been disconnected
The insert requires
extraordinary maintenance
Possible causes
62
Cures
- Check the cleanness of the
flue
pipe,
the
combustion
chamber and the air flow
meter; hermetic closure of the
door and the overpressure
valves.
Then
repeat
lighting procedure
- Other reinstatement
operations must be carried out
by a service center
Reinstatement operations
must be carried out by a
service center
Wait for the insert to cool and
repeat the lighting procedure
The insert continues its normal
operation and safety is
guaranteed by the remaining
devices. It is advisable to
contact a service center
as soon as possible
The insert continues its normal
operation. It is advisable to
contact a service center
as soon as possible
TOPFIRE 80 canalizzabile
the