Wearing Parts - NEPTUN classic NCTF-O 8000 Instrucciones De Uso

Ocultar thumbs Ver también para NCTF-O 8000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
- GB -
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean and check the unit for damage.
Store the pump immersed in water or filled with water at a frost-free place. Do not flood the power plug!

Wearing parts

The UVC lamp, the quartz glass, the filters and the rotor are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Malfunctions
Malfunction
The unit performance is not satisfactory
UVC lamp display is not lit
No water outlet from the pond inlet
16
23587-01-14_GA_Durchlauffilter_N16 16
Cause
Unit has been in operation only for a short time
Water extremely soiled
Excessive fish and animal population
Foam filters soiled
Pump filter housing soiled
Impeller unit blocked
Quartz glass tube soiled
UVC lamp capacity exhausted
Power supply of UVC not connected
UVC lamp defective
Connection defective
UVC overheated
Pump power supply not connected
Pond inlet blocked
Remedy
The complete biological cleaning effect is only
achieved after several weeks
Remove algae and leaves from the pond,
perform a partial water change
Guide value: approx. 60 cm fish length in 1 m³
pond water
Clean filters
Clean pump filter housing
Clean pump
Remove UVC and clean quartz glass
Replace the lamp after approx. 8,000 operating
hours
Connect UVC power plug
Replacing the UVC lamp
Check electrical connection
UVC automatically switches on when cooled
down
Connect pump power supply
Clean pond inlet
31.01.2014 09:41:24

Publicidad

Tabla de contenido
loading

Tabla de contenido