Maintenance of the drive unit
Carbon brushes
The carbon brushes may wear down to the white marking. Replace the carbon brushes with
spare brushes from CIBO only. Using other carbon brushes results in loss of guarantee. . They
may be ordered from CIBO.
You can observe the brush sparks via the air slits. Turn the machine off immediately if the sparks
are too strong. To prevent further significant damage we advise sending the machine to our CIBO
customer service workshops for repair.
Reference number of the the carbon brushes
Finipower 110 V : SMFP 316034930
Finipower 220 V : SMFP 316035510
Cleaning
Ensure that the machine and the ventilation slots are always kept clean so that you can work ef-
ficiently and safely. In extreme working conditions, such as finishing metals, conductive dust can
collect inside the machine. In that case we advise the regular use of a compressor to clean the
ventilation slits. Also use an earth switch in the electric connection.
Drive
Loosening the screws on the drive unit head within the guarantee period is not permitted. The
guarantee is forfeited if these screws are loosened.
You must visit a CIBO service workshop to have the lubricant changed after approximately 1 000
working hours. You must also arrange then for the machine to be inspected to ensure that it still
answers to the applicable safety regulations.