EZ-SCAN 4000 ___________________________________________________________________________
•
Make sure that all the pins are straight and that the connecting surfaces are free of
oils, grease, and moisture.
CAUTION:
Do not force the cable connector into the scanner or into the vehicle
computer connection.
•
Push the scanner cable and vehicle connectors together firmly.
NOTE:
Make sure the scanner cable and vehicle connectors are always properly seated during
all test procedures.
•
Insert the EZ-SCAN cable connector into the top of the scanner.
2.5 -
Set the Time Units for Capture Mode
The EZ-Link scanner can be set up to capture a user defined length of time while in
Capture Mode. The default setting is 1000 ms (1 sec) per frame.
•
To change the Capture Time, press CONFIG from the initial screen.
•
Use the
and
ENTER.
•
Use the
and
•
Use the
and
between 500 and 5000 ms, then press ENTER to select the choice (or press the
CONFIG Key to Cancel and return to the initial screen).
NOTE:
500 milliseconds is one-half a second, 1000 milliseconds is 1 second, and
5000 milliseconds is 5 seconds.
40
arrow keys until 2-System Config is displayed, then press
arrow keys to select 2-Capture Time, then press ENTER.
arrow keys to change Capture Time to the desired number
OPERATING INSTRUCTIONS