PerfectControl MPC01
Changing the settings for batteries A, B and C
➤ Navigate to the "Battery details" menu (page 33), see chapter "Navigating within the
menu" on page 30.
➤ Navigate to the menu page for the battery required.
➤ Press the selector button to access setting mode.
➤ Turn the selector button to mark the value to change.
➤ Set the required value, see chapter "Changing values" on page 36.
Programming the switchable outputs
You can define the switch points for switchable outputs 1–3 on the adapter board
(fig. 5 1, 2, 5, page 5). The set value (10 % - 90 %) is the total capacity of all batteries
connected. If the value for the current total capacity is greater than the set value, then
the output is switched to earth. If the value for the current total capacity is less than the
set value, then the output is not connected to earth.
➤ Navigate to the "Switchable output settings" menu page, see chapter "Navigating with-
in the menu" on page 30.
➤ Press the selector button to access setting mode.
➤ Turn the selector button to mark the value to change.
➤ Set the required value, see chapter "Changing values" on page 36.
Reading charger information and changing settings
➤ Navigate to the "Charger" menu page (page 31, see chapter "Navigating within the
menu" on page 30.
➤ Press the selector button to access setting mode.
➤ Turn the selector button to mark the value to change.
➤ Set the required value, see chapter "Changing values" on page 36.
Reading inverter information
➤ Navigate to the "Inverter" menu page (page 31), see chapter "Navigating within the me-
nu" on page 30.
Viewing battery history
I
NOTE
If the battery is discharged to less than 5 % and then charged to more than
95 % capacity, only one entry is shown.
The menu page shows the date and time of battery charging and discharging processes.
Up to 50 entries are saved.
➤ Navigate to the "Battery history" menu page (page 33), see chapter "Navigating within
the menu" on page 30.
EN
Operating the MPC01
37