Malfunctions
Compressor becomes too hot
Note: No claim is made to the completeness of the possible malfunctions listed here.
Technical data
The following is a table of performance values of individual compressor types.
Model
Voltage
Volt
20A
230/50
25A
230/50
30Ar
230/50
30Ae
230/50
50A
230/50
100A
230/50
Possible causes
Oil level incorrect
Wrong oil type
Air filter dirty
Room temperature too high
or air supply is
inadequate
Compressor excessively
overloaded
Power
Suction
capacity
Watt
litre
135
20
135
20
200
30
200
30
340
50
680
100
Remedy
Check oil level, top up oil if
necessary
Drain oil and replace with com-
pressor oil
Change air filter
Ensure that air supply is
adequate
Check whether compressor is
suitable for load
Pressure
Tank
capacity
bar
litre
6
1.5
6
3.5
8
9
8
4
8
15/24
8
24
Noise
Weight
level
net
dB (A) 1m
kg
38
18
38
16
40
20
40
22
43
25
43
39
GB
19