Krampouz GGCIC30AA Instrucciones De Uso página 15

Placa de cafetería / plancha de gas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6
Then release the knob and allow the burner to heat the hot plate to the suitable temperature.
7
Your appliance is now ready to be used.
Adjustments
In the event of a change of gas, the injectors must be compulsorily changed (as per the indications
given in the table on page 12/13) and the low heat adjusted.
Changing the injectors:
In the case of an appliance already installed, before changing the injectors and making new
adjustments, shut off the tap from the gas pipe or gas cylinder.
Proceed as follows:
1.
Shut off the tap of the gas pipe or the gas cylinder.
2.
Remove the enamelled steel plate, unscrew the screws holding the burner and turn the
appliance over.
3.
Remove the protection by unscrewing the two screws (see figure 3, page 18).
4.
Push on the burner to distance it from the tap.
5.
Unscrew the injector using a spanner of 10 and get the transformation bag (bag of injectors).
6.
Change the injectors and seals adhering to the indications in the table of correspondence of
the different types of supply (table, page 12/13).
7.
According to the gas used, the value from the base of the injector to the burner changes (see
figure 2, page 18 and table, page 12/13).
8.
Move the burner along according to the arrow for a new adjustment (see figure 3, page 18).
9.
After repositioning the burner to the recommended value, screw back the screws in order to
block the burner. Close and screw back on the protection of the appliance. You are advised to
write the new configuration on the data plate of the appliance and erase the old one.
10. Place the changed injector in the transformation bag and store it carefully then proceed to start
up.
Low flame (see figure 4 page 18)
When appliances are adjusted to butane/propane gas, the low heat screw is turned fully to the
right.
If you switch from Butane/Propane gas to Natural gas, this screw must be loosened until the correct
adjustment of the low heat is obtained. The low heat is properly adjusted if the flame does not go out
when going quickly from the maximum position to the minimum position. The flame must be as low as
possible, approximately the equivalent of a needle head on each hole.
The low heat adjustment must be made with the hot plate in position.
- 15 -

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ggcic40aa

Tabla de contenido