3.5. Maintenance and Shutting the System Down
Maintenance work may only be carried out by expert trained personnel. The Thermosiphon System must be regularly checked
and documented in accordance with the initial installation and maintenance checklist contained in the installation instructions. 6
The panel surface must be protected from direct sunlight during shutting-down, during maintenance work and when draining the
hot water storage tank. The service itself should be carried out in the morning if possible.
In order to be able to replace or to service the Mg anode, you must make sure that there is no hot water left in the storage tank.
ature has dropped to the line temperature. (See hydraulic circuit diagram; Caution: Danger of scalding!). The storage tank can
then be drained by interrupting the process water infeed line and unscrewing the safety valve in the process water circuit.
CAREFUL OPENING THE SCREWED FITTINGS - STORAGE TANK IS UNDER PRESSURE! DANGER OF INJURY AND SCALDING!
away more quickly and will need to be replaced earlier. In these cases, we recommend an inspection every 6 months after com-
missioning of the system, in order to determine the ongoing maintenance intervals. If the conductivity of the water is less than
current anode.
age tank must be drained. (Caution: Danger of scalding, system is under pressure).
Water quality is subject to considerable regional variation and, in some cases, may cause problems due to corrosion or lime scale
deposits. Warranty claims due to water-related corrosion or lime scale deposits are excluded. We would like to point out here
that specifying a certain water quality is no guarantee that corrosion will not occur. Instead, this is intended as a guideline to
avoid damaging critical water applications. A summary of critical water parameters and the recommended limit values are includ-