Solenoid Valve Removal (Standard Models) - Clarke Clean Track 16 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

AUTHORIZED PERSONNEL MAINTENANCE

SOLENOID VALVE REMOVAL (STANDARD MODELS)

1
Drain the recovery and solution tanks and tip the machine over onto its side.
2
See Figure 8. Remove the (2) (A) Screws.
3
Tip the machine back upright, grab hold of the Operator's Handle (1) and push down to tilt the entire recovery / solution tank assembly back.
4
Disconnect the (2) solenoid valve wires. NOTE: Make note of their connection locations for reassembly.
5
See Figure 9. Tip the machine back over onto its side and disconnect Solution Hose (A) from the Solution Pump.
6
Remove the (2) (B) Screws then remove the Nozzle Assembly from the machine. The Solenoid Valve (C) can now easily be disassembled from
the Nozzle Assembly.
7
Follow the above steps in reverse order to install the solenoid valve.
FIGURE 9
EN
FORM NO. 56041660 - Clean Track
ENGLISH / A-13
16, 18 - A-13
®

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Clean track 18Clean track 18 wash&rinse56266000562660015626600256266132 ... Mostrar todo

Tabla de contenido