Solenoid Valve Removal (Wash & Rinse Model) - Clarke Clean Track 16 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A-14 / ENGLISH
AUTHORIZED PERSONNEL MAINTENANCE
SOLENOID VALVE REMOVAL (WASH & RINSE MODEL)
1
Drain the recovery and solution tanks and tip the machine over onto its side.
2
See Figure 8. Remove the (2) (A) Screws.
3
Tip the machine back upright, grab hold of the Operator's Handle (1) and push down to tilt the entire recovery / solution tank assembly back.
4
Disconnect the (2) solenoid valve wires. NOTE: Make note of their connection locations for reassembly.
5
See Figure 10. Tip the machine back over onto its side and disconnect Solution Hose (A) from the Solution Pump.
6
Disconnect Tube Connector (B) and remove Elbow (C).
7
Remove the (2) (D) Screws then remove the Nozzle Assembly from the machine. The Solenoid Valve (E) can now easily be disassembled from
the Nozzle Assembly.
8
Follow the above steps in reverse order to install the solenoid valve.
FIGURE 10
A-14 - FORM NO. 56041660 - Clean Track
EN
16, 18
®

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Clean track 18Clean track 18 wash&rinse56266000562660015626600256266132 ... Mostrar todo

Tabla de contenido