LMB
14. Descaling
Regular descaling is key to your steamer functioning properly.
i
Depending on water hardness, descale the steam wallpaper stripper
after 10 – 15 fills. Units which are defective due to a lack of descaling
are excluded from the guarantee!
•
Use a standard proprietary descaling agent. Observe the manufacturer's instructions
for use!
•
Mix the descaling agent with water (ratio 1:1).
•
Fill the steam wallpaper stripper with around 3.5 litres of descaling solution.
•
Switch the steam wallpaper stripper on for 10 minutes.
•
Switch the steam wallpaper stripper off again and unplug.
•
Leave the descaling solution to work for 30 minutes.
•
Then fully empty the steam wallpaper stripper.
•
Thoroughly rinse the unit two to three times with clear water to remove all descaling
solution residue.
15. Important Note regarding Product Liability!
In accordance with an EC directive, the manufacturer is liable for this product only if all parts
originate from or were approved by the manufacturer and the tools are assembled and
operated correctly. The use of other accessories and spare parts can partially or completely
invalidate the liability.
16. Correction of Malfunctions
Malfunction
Unit fails to boil
Cause
•
The thermal cut-out has operated
•
Usage of an extension lead
Remedy
➞ Switch off, allow to
cool, refill with water
then switch on again
➞ Check that the thermal
reset button has not
tripped out.
➞ Check that the
extension lead is rated
at minimum of 15
Amps (EU)/ 13 Amps
(UK) - 230V unit only
and fully unwound.
EN
11