Using Your Humidifier
(continued)
Check
Filter
Indicator
The ability of any humidifier
to efficiently
supply
humidity
output
relies heavily
on the
condition
of the filter. As the filter loads with
impurities
it gradually
loses its wicking
capability.
When this happens,
moisture
output
is reduced
and the humidifier
has to
work longer to satisfy the selected
setting.
This humidifier
has a check filter reminder
timed to appear
after 720 hours of motor
operation.
When the display shows an
alternating
"CF"
and "room humidity"
setting
at 5 second
intervals
it is a
reminder
to check the filter condition.
NOTE:
Some areas
have high water
mineral
content
causing
the need for more
frequent
filter changes.
Refer to "Replacement
and Care of Filter"
on page 1 I. If a build-up
of deposits
or
severe discoloration
is evident
replace
the
filter to restore maximum
efficiency.
Control
Lock Out
To avoid unwanted
tampering
with the
humidifier
settings
the controls
can be
locked.
Activation
Procedure
After the humidifier
functions
have been
set up, press and hold the power
button
down for 5 seconds.
The display
will show
"CL"
for 5 seconds;
release
the power
button
and the control
will resume
the
display
of the room humidity.
The
humidifier
will continue
to function
with
the locked
in settings.
If buttons
are
operated
while
"CL"
is active,
the "CL"
is
displayed
and settings
are unaffected.
Deactivation
Procedure
To deactivate
the "CL"
function
simply
press
and hold the power button
for 5
seconds.
"CU'
will flash and then
resume
the display
of room humidity.
Check
Filter
Display
Humidistat
The humidistat
located
on the power
cord
senses
the percentage
of humidity
in the
air. It causes
the humidifier
to cycle
on
and off to maintain
the selected
humidity
SET point. The fan will turn on if the
"ROOM"
reading
falls 3% below
the SET
point and will continue
to run the
humidifier
until a reading
of 1% above the
SET point
is achieved.
The fan will turn
off until the ROOM
reading
falls 3%
below
the SET
point again.
NOTE:
Be sure humidistat,
which
is
located
on the power
cord,
is free from
obstructions
and is away from any hot air
source.
10