Page 18
Jandy Heat Pump Models EE-Ti Installation and Maintenance Manual
4.
Connect the wiring from the pool/spa control
system to the heat pump remote control terminal
(See Figure 12b).
5.
Restore power to the heat pump and the pool/spa
control system.
4.5.2.3 Confi gure the Control Panel
1.
Make sure the control is in the OFF mode.
2.
To enter the Service Setup mode, press and hold
the MENU, POOL, and SPA buttons for 5
seconds.
NOTE The display will revert back to OFF after one
minute since the last key press.
3.
Press the Up or Down button to display
REMOTE. The SELECT REMOTE OFF
(default remote) appears, use the Up or Down
button to scroll through the Remote options. When
you reach REMOTE TSTAT, press the MENU
button to select the remote. Press POOL or SPA
to exit the Service Setup mode.
4.
Press SPA. For heating, adjust the setpoint to the
maximum setting. For chilling, adjust the setpoint
to the minimum setting.
4.5.3
Four-Wire Connection to AquaLink
RS 485 Communication
1.
Confi rm the EE-Ti heat pump and AquaLink RS
software revisions are compatible (see Figure 14).
NOTE Only a revision "N", or higher, program chip in
the RS system will support the EE-Ti heat pump
interface.
2.
Turn off the power to both the heat pump and
the RS control and open the RS Power Center
enclosure and remove the front dead panel.
3.
Remove the two (2) screws holding the bezel in
place and turn the bezel over to view the circuit
board on the back.
4.
Locate the programmed chip on the Power Center
Board. In the center of the chip is the revision
letter. If the revision letter is "
step 5. If the revision level is "
replace the board or connect as shown in Section
4.5.2.
5.
Use 22 gauge 4-conductor wire (Jandy Part No.
4278) to run between the heat pump and the RS
control, and match the wire color order.
6.
The wires coming from the EE-Ti heat pump can
be "doubled up" on the red terminal bar with the
four (4) wires coming from the indoor controller.
NOTE If you need to install more than two (2) wires in
each terminal, order a Jandy Multiplex PCB Kit,
®
" or higher go to
N
" or lower,
MMM
®
JANDY AquaLink RS
06/26/04 MON
6:00 PM
FILTER PUMP OFF
AIR 79°
EQUIPMENT ON/OFF
OR
ONETOUCH ON/OFF
MENU / HELP
4-Conductor
Wire
RED
BLK
YEL
GRN
AE-Ti Heat Pump Power Interface
Figure 14. EE-Ti Heat Pump Connection to Power
Center
which includes the Multiplex Board (Jandy Part
No. 6584). Never put more than two (2) wires
into each of the pins of the terminal bar.
7.
Check all wiring, then apply power to both the
heat pump and the RS control system. Operation
can be verifi ed in either Service or Auto mode. See
the RS Control System manual for instructions
about operation.
When the EE-Ti heat pump is first powered and
there is an RS control connected to the heat pump, the
display on the heat pump will show "JANDY REMOTE
ONLINE PUSH MENU TO DISABLE" . When the
EE-Ti heat pump is online with the RS control, all
functionality of the control on the heat pump is disabled.
The heat pump functions can be controlled only at the
RS unit.
To temporarily use the heat pump controls, press
the
button. The message "JANDY REMOTE
MENU
ONLINE PUSH MENU TO DISABLE" will disappear
from the heat pump display. All functionality has now
been returned to the control on the heat pump. In this
mode the RS unit is no longer controlling the heat
pump.
To return the functionality to the RS unit, cycle
(turn off and then turn on) the power to the heat pump,
or press the MENU button for 5 seconds to enter the
User Setup Mode and then enable the Jandy Remote.
4 3 2 1
4 3 2 1
4 3 2 1
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
S1
RESET
RS6 & RS8 ONLY
RS8 ONLY
POOL MODE
AUTO
SPA MODE
SERVICE
SPA DRAIN
HEATER
SOLAR
TIME OUT
SPA FILL
S2
OPTIONAL
RS Power
Center