Flotec FPSC2200A-10 Manual Del Usuario página 6

Ocultar thumbs Ver también para FPSC2200A-10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
Figure 5
5A. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit. The cir-
cuit must be grounded and should be dedicated
to the sump pump.
5B. The pump is supplied with a 3-wire cord set with
grounding-type plug. Plug the switch directly into
the outlet and plug the pump into the opposite
end of the switch's plug.
Electrical shock hazard. Always
ground the pump to a suitable electrical ground,
such as a grounded water pipe, a properly ground-
ed metallic raceway, or a ground wire system. Do
not cut off the round ground pin.
For parts or assistance, call Flotec Customer Service at
Figure 6
6A. After you have installed the piping, check valve,
and float switch, the pump is ready for operation.
6B. Check the pump by filling the sump with water
and observing the pump's operation through one
complete cycle. For switch settings see the
Electrical and Switch Specifications chart on
Page 5.
Failure to make this operational
check may lead to improper operation, premature
failure, and flooding.
1-800-365-6832
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fpsc2250a-10Fpsc3200a-10Fpsc3250a-10Fpsc4550a-10

Tabla de contenido