8. TECHNICAL DATA

Technical data
External dimensions (H×W×D mm)
Nominal power
Nominal voltage
Frequency
Current consumption
Noise level
Net weight (without Filter)
Activated carbon filter weight (incl filling 3500 g)
Volumentric flow (mounted on the cabinet)

9. REPAIRS

10. FUNCTIONAL CHECK • CARE • MAINTENANCE
1212
UFA.20.30(xxx)
210×300×550
8,5 Watt
85–264 V
50/60 Hz
0,13 A
23 dB
12 kg
4,2 kg
25 m /h
CAUTION:
The figures in the table are provided as a guide, and are not to be used in the sense of assured
properties. They conform to the state of the art as and when the operating instructions were printed.
Changes to these values without notice as a result of further technical development are explicitly
permitted.
The extraction air inlet on the top is only to be repaired by specialists trained for this very purpose.
Given damage the appliance is to be repaired or replaced by the manufacturer. Please contact the
costumer service.
To ensure reliability, the extraction air inlet on the top should be serviced and checked as to func-
tioning by a specialist at least once a year. At the same time the fitted filter unit is to be replaced
at least once a year - or sooner should the saturation limit be reached.
The integrated ventilation and filter saturation monitoring system electronically checks on func-
tionality. As a result, the extraction air inlet on the top function is constantly examined during
operation. The activated carbon filter of the extraction air inlet on the top must be replaced soon
after the red LED of the filter display blinks. Only our trained service technicians are to change the
filter, which is to be rapidly requested under the Service hotline. Having the filter changed by the
asecos service ensures that contaminated activated carbon is recycled in a defined disposal chain.
Clean the outside of the extraction air inlet on the top with a soft cloth and a common, mild
household cleaner. Before cleaning, disconnect the extraction air inlet on the top from the mains
by pulling out the C13 cable! Make sure that no moisture can penetrate into the inside of the
extraction air inlet on the top during cleaning.
SERVICE: In case of questions please contact Customer Service!
Tel: +49 6051 92 20 0*
(* at local rates in the german fixed network)
Load capacity of the voltage-free alarm contact
Max. nominal voltage AC
Max. permanent current at 250 V AC
Max switching power (ohms)
Max switching power (elektro-magnetic)
Single-phase motor load (inductive)
Max. switching current at 30 V DC
Max. switching current at 115 V DC
Max. switching current at 230 V DC
230 V
10 A
1500 VA
300 VA
185 Watt
10 A
0,2 A
0,12 A