CONTROL PANEL

The KTB4 interface control panel is composed of 7 leds: 3 yellow leds (LINK1, LINK2, LINK3)
and 4 green leds (SENS1, SENS2, SENS3, SENS4).
The LINK leds can be in the following states:
LED STATE
OFF
Always ON
Flashing led
Rapidly flashing led
The SENS leds can be in the following states:
LED STATE
OFF
Always ON
Flashing led

TECHNICAL DATA

MODEL
INPUT CHARACTERISTICS
Supply voltage
(1)
Maximum absorption
AMBIENT CHARACTERISTICS
Operating temperature
GENERAL
Dimensions (W x H x D)
Weight
Communication interface
EMC Class
(1)
The instrument can reset itself at a voltage less than 8 Vdc.
®
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
KTB4 - REV002A
OPERATING - TECHNICAL DATA
DESCRIPTION
The interface is off.
Connected
Unconnected If the battery charger is off or not present inside the group,
this indication is correct. If the battery charger is switched on, check the
connection of the data transmission cable, the unit configuration, and the CAN
termination.
The dip-switch configuration is incorrect.
DESCRIPTION
No sensor is connected.
The temperature of the batteries is between -40° C / +120° C.
The temperature of the batteries is outside the range of –40°C +120°C.
If the sensor is short-circuited or open, "F" appears on the battery charger
display.
KTB4
from 8 to 30 Vdc
60 mA
from -20 to + 70° C
134 mm x 63 mm x 94 mm
180 g
CAN BUS with differential transceiver
EN 55022-B
GB
19