Jandy Pro Series TruClear Manual De Instalación Y Operación página 7

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Jandy
Pro Series TruClear
Chlorine Generating System
®
The power pack must be installed at least 0.6 m (2 ft.) vertically off the ground.
In the US, the power pack must be installed at least 1.5 m (5 ft.) from the inside wall of your swimming pool or
spa; in Canada, the power pack must be installed at least 3 m (10 ft.) from the inside wall of your
swimming pool or spa.
The Jandy Pro Series chlorine generating device must be installed outdoors only. The cell must be installed
horizontally with the cord facing upwards to avoid buildup of flammable gases which can result in FIRE OR
EXPLOSION.
The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool.
To Reduce the Risk of Fire, install pool equipment in an area where leaves or other debris will not collect on or
around the equipment. Keep surrounding area clear of all debris such as paper, leaves, pine-needles and other
combustible materials.
To minimize risk of severe injury or death, filter, pump, and/or chlorinator should not be subjected to the piping
system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These requirements are gener-
ally not intended to apply to the pool equipment, such as filters, pumps, or chlorinators.
Jandy pool equipment is pressure tested at the factory.
If, however, the WARNING cannot be followed and pressure testing of the piping system must include the filter,
pump, and/or chlorinator, BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:
• Check all clamps, bolts, lids, lock rings, and system accessories to ensure they are properly installed and se-
cured before testing.
• RELEASE ALL AIR in the system before testing. AIR PRESSURE must NOT be used for pressure testing.
• Water pressure for test must NOT EXCEED 35 PSI.
• Water temperature for test must NOT EXCEED 100°F (38°C)
• Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.
Notice: These parameters apply to Jandy equipment only. For non-Jandy equipment, consult the equipment
manufacturer.
|
Installation & Operation Manual
WARNING
WARNING
SAVE THESE INSTRUCTIONS
Page 7
ENGLISH

Publicidad

Tabla de contenido
loading

Productos relacionados para Jandy Pro Series TruClear

Tabla de contenido