3.
Quick Connect Multi System Installation
Connect Cord.
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).
System Diagram
Quick Connect
Cord
Cord
Connector
Typical Plumbing
Make this distance as short
as possible.
* The hot water temperature
will become unstable as the
pipe length increases.
the cold water supply piping to prevent heat loss and freezing of pipes when exposed to
excessively cold temperatures.
Cord
Connector
Distance at center: 20.3 - 36.3 in. (515 - 922mm)
Union
Quick Connect Cord
Union
Pressure
Relief Valve
Shutoff Valve
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
* When connecting two units, use only a
single remote controller.
Terminal Block
Remote Controller
Remote Controller Cord
Gas Supply Piping
G
Cold Water Supply
Hot Water
Distance on sides
2 - 18 in. (50 - 457mm)
Union
Gas Valve
Shutoff Valve
Note: Connect the remote
controller to only one
of the units.
Size the piping to allow for the
maximum ow rates of the units.
Hot Water
Cold Water
Shutoff Valve
The back ow preventer is
put up before it diverges.
3