Waeco 4-Way Manifold Instrucciones De Montaje página 14

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
Operating the 4-way manifold
➤ Close the "HIGH" knob (red).
➤ Close the "LOW" knob (blue).
Now fill the air conditioner as follows:
➤ Open the "HIGH" knob (red) or the "LOW" knob (blue) as needed.
➤ Open the "REF" knob (green) (fig. 2 10, page 3) to fill refrigerant via an
external refrigerant bottle until the required amount has been reached.
5.3
Completing the filling
➤ Close all valves.
➤ Detach all connections.
➤ Recycle the refrigerant from the hoses.
5.4
Performing the diagnosis/pressure test
➤ Close all valves.
✓ The pressure in the air conditioner is displayed.
5.5
Recovering refrigerant
➤ Open the "HIGH" knob (red) or the "LOW" knob (blue) as needed.
➤ Open the "REF" knob (green) (fig. 2 10, page 3) to fill the refrigerant out
of the air conditioner into an external refrigerant bottle with the help of a
suction station.
➤ Close all valves.
✓ If the air conditioner is completely empty, the displayed pressure is 0 bar
(0 Pa).
➤ If necessary, open the knobs again until the air conditioner is completely
emptied.
14
4-way manifold
EN

Publicidad

Tabla de contenido
loading

Productos relacionados para Waeco 4-Way Manifold

Tabla de contenido