GB
and water solution over them and watching for bubbles, which would indicate a
leak.
After testing dry off traces of detergent.
For your safety
Do not check for leaks with a naked flame!
Do not smoke while checking for leaks!
10. Gas equipment system
The gas equipment consists of a multiple value (B) [value with built-in
thermoelectric ignition control], the piezo-gas lighter (E), a burner with sparking
plug and the gas-thermostat.
Knob (B) can be turned to 2 function positions:
: large flame = gas-flow open;
:
out position = gas supply to burner is closed.
If, for any reason the gas flame extinguishes, the ignition control is working
automatically and shuts off gas supply.
11. Igniting the gas burner
1. 1. 3-way-switch (D) should be in position "0"
2. Open gas cylinder or pressure regulating valve.
3. Turn knob (F) to position 6.
4. Turn knob (B) anticlockwise to the MAX position, press and hold down.
5. After approximately 10 seconds, press knob (E) several times. After ignition,
hold down knob (B) for a further 20-30 seconds before releasing.
The flame can be controlled by aperture (C).
Should no ignition occur, repeat the ignition process after 1 minute.
(This could lake longer than 10 seconds if the unit has been out of operation
for a prolonged period or after replacing the gas cylinder. Cause: air in the
lines.)
6. When a sufficient low internal temperature of the refrigerator has been
reached, it may be necessary to set the control knob (F) to MIN-position,
particularly at night, in cool weather conditions or when the refrigerator is
only lightly loaded, respectively the ambient temperature is below 18°C, in
order to avoid overfreezing the contents.
12. Shutting down gas operation
1. Close gas cylinder or pressure regulating valve.
2. Turn knob (B) clockwise to the off position.
32
(Fig. 1)
(Fig. 1/4)
(Fig. 1+5)