Hose Connections - Greenlee HFC30 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Hose Connections

Do not disconnect tool, hoses or fittings while the
power source is running or if the hydraulic fluid is
hot. Hot hydraulic fluid can cause serious burns.
Tool Port Identification
One of three methods is used to identify the pressure
and return ports of Greenlee Utility tools. Match your
tool to this table.
Pressure Port
P
In
9/16"–18 SAE O-ring Boss
(smaller port)
CONNECT TO TOOL
RETURN PORT
CONNECT TO TOOL
PRESSURE PORT
Greenlee / A Textron Company
Return Port
T
or
Out
or
3/4"–16 SAE O-ring Boss
(larger port)
HFC30 Flow Control Valve
Connecting Hoses
1. Move the flow lever on the power source to the
OFF position.
2. Stop the hydraulic power source.
3. See the illustration. Connect a return hose to the
return port on the power source, then to the power
source return port on the valve. Connect the other
return hose to the tool return port on the valve, then
to the return port on the tool.
4. Connect a pressure hose to the pressure port on
the tool, then to the tool pressure port on the valve.
Connect the other pressure hose to the power
source pressure port on the valve, then to the pres-
sure port on the power source.
Disconnecting Hoses
1. Move the flow lever on the power source to the OFF
position.
2. Stop the hydraulic power source.
3. Disconnect the hoses in the reverse order of the
connection sequence.
4. Install dust caps over the ports to prevent
contamination.
6
4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070
CONNECT TO
POWER SOURCE
RETURN PORT
CONNECT TO
POWER SOURCE
PRESSURE PORT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

49550

Tabla de contenido