5. DMX connection and DMX protocol
5.1 DMX addressing:
5.1.1 The device is controlled by universal DMX 512 protocol,
DMX address is the start channel used to receive instructions
from the external controller. For independent control, each
fixture must be assigned its unique address control channels.
For example, this device has four channel modes: 10/13, if
we set the mode at standard 13 channels mode, and there
are several models need to be independently controlled, we
just simply address first fixture at 1, and second fixture at 11,
third one at 21, etc.
If the devices have the same address, they will behave syn-
chronically.
DMX addressing is limited, don't set the address so high that
without enough control channels for the fixtures.
Display is flashing when no DMX signal is received.
5.1.4 Connection: us DMX cable with 3-pin XLR-plugs to
connect the controller with the fixture or one fixture
with another.
ION 132F
ENGLISH VERSION
5.1.2 This device is equipped with 3-pins DMX in and out
sockets only. Pin 1 = GND | Pin 2 = Signal (-) | Pin 3 = Signal (+)
5.1.3 The termination is prepared by soldering a 120Ω resis-
tor between pins 2 and 3.