The device can be operated continuously
for long periods of time without the
periodic emptying of the tank by means of
a discharge tube (not supplied, 10).
•
Check that the dehumidifier is switched off
and remove the plug from the mains.
•
Remove the rubber cap supplied (7) at the
back from the outlet hole of the outlet
connector (6).
•
Connect the tube (12 mm internal diameter and not more than 1.5 m in length) to the outlet
connector and an external drain. Check: that the tube is secured and cannot slip off, and that the
drain is at a lower level than the connector.
•
Make sure that the drainage pipe is sloping and that it is not higher than the level of the connector
(see figure): otherwise the water will remain in the tank. Also check that the tube is not choked,
bent or clogged.
Warning: if you are not using the continuous drainage feature, remove the drainage pipe from the
outlet and insert the rubber cap in the connector.
CLEANING AND MAINTENANCE
Important: before performing routine cleaning, remove the plug from the mains.
• To clean the tank, use water with a regular dishwashing detergent, and wipe with a soft sponge (do
not use steel wool or abrasive products). Rinse and dry thoroughly. The water temperature should
not exceed 40 °C. It is important that the tank is washed well and immediately after use to avoid the
formation of bacteria or odours.
• Periodically check that the air filter (4) is clean and that it is not clogged
by lint or fluff. To remove the filter, press the tab (11) in and push the
filter upward, as shown. To remove dust, use a brush or a vacuum
cleaner, taking care not to damage any part. If the filter is very dirty,
wash it in warm water and rinse several times. The water temperature
should not exceed 40 °C. After washing, allow it to dry completely
before replacing it. Do not wash it in the dishwasher.
Copies of the I/B. Please reproduce them without any
changes except under special instruction from Bimar
(Italy). The pages must be reproduced and folded in
order to obtain a booklet A5 (+/- 148.5 mm width x 210
mm height). When folding, make sure you keep the good
numbering when you turn the pages of the I/B. Don't
change the page numbering. Keep the language
integrity.