Descargar Imprimir esta página

Product And User Description - König Electronic SEC-SA200 Manual De Uso

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30

Product and user description:

1. ALARM indicator
2. TEST button
Testing the smoke alarm
Like any other electronic device, smoke alarms are not foolproof. Smoke alarms contain electronic
components that can fail or wear out at any time.
We recommended that you test the smoke alarm every week to make sure it is working properly.
Push and hold the test button until the alarm sounds for a few seconds. The (red) alarm indicator (1) and
(green) learn indicator (4) will flash for a moment. If the alarm does not sound, check if the battery indicator
flashes once every 45 seconds. If this is not the case and testing fails, please replace the batteries
immediately.
Battery indicator
The battery indicator flashes every 45 seconds to show that the smoke alarm is working properly. When the
battery indicator flashes and gives a short beeping sound, it indicates that the battery has a low capacity
and should be replaced immediately.
3. LEARN button
Follow the next steps to set the MAIN smoke alarm and ASSISTANT smoke alarm(s) to create a smoke
alarm system with 2 or more SEC-SA200's.
1. Press the LEARN button two times. The LEARN indicator turns from red to green. This smoke alarm will
be the MAIN smoke alarm. Ensure the LEARN indicator is green before proceeding.
2. Press the LEARN button of the ASSISTANT smoke alarm(s) once. The ALARM indicator(s) turns on red.
Ensure the ALARM indicator(s) are red before proceeding.
3. Press the TEST button of the MAIN smoke alarm for several seconds in order to send out the learn
signal to the ASSISTANT smoke alarm(s). The ALARM indicator flashes and the smoke alarm sounds.
The ASSISTANT smoke alarm(s) receive the signal and sounds.
4. Press the TEST button on each ASSISTANT smoke alarm(s) for several seconds in order to send out
the learn signal to the MAIN smoke alarm. The MAIN smoke alarm receives the signal and sounds.
Note: the number of smoke alarms is unlimited. The maximum range between 2 smoke alarms to
communicate with each other is 40 metres.
3

Publicidad

loading