Commissioning
Installing the app on a mobile device
Install the Deepfield Connect – Field Monitoring app from the
Google Play Store or the Apple App Store. Search term: deep-
field field monitoring.
To install the app, follow the instructions provided by your
operating system.
Starting the app and logging in
You will have entered your e-mail address and a password
when you ordered a monitoring station from the Deepfield
Connect online shop. You can use this information to log into
the app. If you have forgotten your password, you can reset it
by selecting the "Forgotten password" option.
Alternatively, you can register again. Deepfield Connect must
be able to contact you via the e-mail address that you provide
when registering.
Start the app.
Select "log in".
Enter your login data or select "register".
If you are registering again, you will be shown the criteria for
creating a secure password.
App functions
The app provides the following functions:
– Field overview: Displays the measured values for the
fields.
– Status: Displays the current measured values and humid
temperatures. Displays the measured values and humid
temperature profile for the past 6 hours. Location-specific
weather forecast.
– History: Displays past measured values in a daily, weekly
or monthly view. Data export of historic measured values.
– Alarm: Switch alarms on/off. Set limit values for tempera-
ture and moisture.
–
Calibrate the soil moisture sensor. Changes to field
information and monitoring station.
– Monitoring stations: Create monitoring station and assign
fields. Delete monitoring station. Displays battery status.
Transmitter search help.
– Share: Allow or deny other users read-only access to sepa-
rate fields.
– Settings: Turn alarm signals on and off for selected fields.
Display license and version information. Contact Deepfield
Connect.
The main menu can be opened by swiping a finger from the
left edge to the right edge of the screen. The main menu can
also be reached from each submenu by pressing the menu
symbol
.
Robert Bosch Start-up GmbH, Deepfield Connect
Switch on transmitter, create field and assign
monitoring station in the app
Before the system can function, you must:
– Insert the battery in the transmitter
– Switch on the transmitter
– Create a new field in the app and
– Assign the monitoring station to the field.
You should complete these four steps before installing the
monitoring station in the field.
Inserting the battery
Also see figure 5, page 3.
NOTE
Risk of damage!
Penetrating water or chemicals may damage or
destroy the monitoring station. Only insert the battery
in a clean and dry environment.
Open the battery compartment.
Insert the battery connector into the socket.
Place the battery and the cable in the transmitter. The
cable should be underneath the battery if possible (see
figure 5, page 3).
Close the battery compartment cover and lock it carefully
with the two screws.
Switching on the transmitter
The magnet supplied is required to switch the device on. The
status LED displays the progress.
Hold the magnet against the recess on the transmitter (see
figure 4, page 3).
The LED will light up in red and then green before going out.
You can then remove the magnet from the casing. The trans-
mitter will be ready 20 minutes after it has been switched
on.
The transmitter cannot be switched off using the magnet. If
required, the transmitter is switched off by Deepfield
Connect over the cellular network.
Holding the magnet against the transmitter ready for use will
test the cellular network signal strength – see "Testing the cel-
lular network" on page 16.
Creating a new field
Now create a new field and assign the transmitter to this field.
Open the main menu and select "Fields > Create field".
Follow the instructions on the display: Enter the basic data
for the field, connect the monitoring station and install the
monitoring station.
Linking the monitoring station to the field
Follow these steps to link a monitoring station to a field that
you have already created in the app:
Open the main menu and select "Monitoring stations".
Select the respective monitoring station. In the next win-
dow, under "Assigned to field" select the respective field.
English | 15