DIP-SWITCH FUNCTIONS
Dip N°
FUNCTION
Dip 1
Step/step P/P
Dip 2
Electronic clutch
Dip 3
Automatic closing
Dip 4
1 or 2 Motors
Dip 5
Slow motion
percentage
Dip 6
Battering ram
Dip 7
Door delay
Dip 8
Phototest
N.b.:each function variation is confirmed upon completion of closure
The tests of maximum force were carried out in the following conditions:
A.
Weight for each door 200Kg. Length of each door 2mt.
B.
Setting of Dip switch: Dip2=OFF Dip5=ON Dip4=OFF
The setting of the other dip-switches does not affect the result of the test
ON
First Impulse Opens and accepts only
re-opening during closing
Maximum Force – minimum sensitivity
to obstacle
Automatic closure activated, enables
Automatic Operation
Operation with 1 Motor
30% deceleration of travel
Before opening performs a brief
closing of door M1
In closing door M1 is activated after 7
sec.
Enabled, at each opening a check is
made of connected device
19
OFF
One Impulse Opens
One Impulse Stop
One impulse Closes
(whether using input P/P Term.
N.15 or from the Remote Control)
Minimum Force – Maximum
sensitivity to obstacle
Automatic Closure not enabled,
Semi-automatic Operation enabled
Operation with 2 motors
10% deceleration of travel
Disabled
In closing door M1 is activated after
3 sec.
Disabled
GB