Quick Guide
Mode 1
1.
Enter the main menu.
2.
Go to parameter group 1-** Load and Motor.
3.
Press [OK].
4.
Set motor parameters using nameplate data for
parameter group 1-2* Motor Data.
5.
Go to 1-29 Automatic Motor Tuning (AMT).
6.
Press [OK].
7.
Select [2] Enable AMT.
8.
Press [OK].
9.
The test runs automatically and indicates when it
is complete.
Mode 2
1.
Enter the main menu.
2.
Go to parameter group 1-** Load and Motor.
MG02BB4P
Quick Guide●Kurzanleitung●Guide rapide●Guía rápida●Guia Rápido●Краткое
руководство
3.
4.
5.
6.
7.
8.
9.
NOTICE
In mode 2, the rotor rotates during the AMT progress.
Do not add any load on motor in this AMT progress.
Danfoss A/S © 05/2016 All rights reserved.
Press [OK].
Set motor parameters using nameplate data for
parameter group 1-2* Motor Data.
Go to 1-29 Automatic Motor Tuning (AMT).
Press [OK].
Select [3] Complete AMT with Rotating motor.
Press [OK].
The test runs automatically and indicates when it
is complete.