The iControl mobile is an electronically controlled
solenoid block, which has a mixed water connec-
tion and must be connected with 3 consumers.
These consumers can be activated simultaneously,
individually, in twos or threes.
Standards and guidelines:
The use of the product is warranted by the following guidelines::
•
EN 15200
•
EN 60335-2-105
Safety Notes:
•
The shower system may only be used for bathing, hygienic and
body cleansing purposes.
•
Children must not use the shower system without supervision.
•
Children as well as adults with physical, mental and/or senso-
ric impairments must not use this shower system without proper
supervision. Persons under the influence of alcohol or drugs are
prohibited from using this shower system.
•
Do not allow the streams of the shower touch sensitive body
parts (such as your eyes). An adequate distance must be kept
between the shower and you.
•
The hot and cold supplies must be of equal pressures.
•
The product is not designed to be used with steam baths!
Electrical connection:
•
The installation and testing work must be performed by a skilled
electrician in observance of VDE 0100 part 701 and IEC 60364-
7-701.
•
Only one socket is required for the electrical connection. The
power is supplied via an external transformer.
•
No easily inflammable material is allowed in the immediate
vicinity.
•
The ambient temperature must not be higher than 50ºC.
•
The entire power is supplied via a 230V/N/PE/50Hz AC con-
nection.
•
The system must be protected via a leakage current protective
device (RCD/ FI) with a measurement difference current of ≤
30 mA.
•
If a potential equalisation is required, this must be done on site.
•
The current version of the applicable regulations from VDE, local
authorities and utility companies must be observed for electric
installation work.
•
It must be ensured that the product can be disconnected from the
mains. Either via a freely accessible plug or via an all-pin switch
as per EN 60335-1, sect. 24.3
10
English
Technical Information
The iControl mobile must be installed together
with the highflow thermostat (in the wall; part no.
15715000 + 01800180) and connected with the
included empty conduit.
This special empty conduit connects the
solenoid block to the receiver!
Outlet 1
hot
Assembly see page 133 + 135
Starting on page 133, different installation designs
with connection examples are shown to ensure a
flawless installation and function.
Installation Instructions:
•
Important! The fitting must be installed, flushed and
tested after the valid norms. (Installation to EN 1717)
See installation instructions::
Raindance Rainfall 28411000
Raindance Rainmaker 28403000 / 28404000 / 28417000
/ 28418000
•
Any work may only be carried out in a de-energized state.
•
The basic body 15941180 can only be installed vertically!
Installation with adjustment ring (A) only possible in the front
and middle sections!
•
All components must remain accessible.
Concealed installation:
•
"iBox iControl mobile" must be installed above "iBox High
Flow".
•
The mixed water flows from the output "iBox High Flow" and
flows into the input "iBox IControl mobile".
Outlet 2
Input
Outlet
•
Depth of fitting: _1e mm to _1f mm.
•
The iBox can depending on the building application be mounted
in different ways, Installation examples please see page 121.
iControl mobile
Outlet 3
High Flow
cold