SETTING THE INTERNAL TEMPERATURE
Connect the DC power supply. Press and hold the button ON/OFF to start the refrigerator. The LED display
on the control panel would be lighted and the interior temperature would be displayed.
Press the button  and  to adjust the temperature. Press the button  to increase while the button 
to decrease the temperature.
SETTING THE UNIT OF MEASUREMENT OF THE TEMPERATURE
With the refrigerator switched off, press and hold the SET + + buttons at the same time for a few
seconds to access the parameter settings.
Press the + buttons to scroll to the function (F - C), press the SET button to enter the parameter and
press the + buttons to change the setting.
Without having to press any other button to confirm, the display will automatically save the setting and
exit programming mode.
OFF-SET VALUE
This is the information needed to align the temperature shown on the display with the actual temperature
inside the refrigerated compartment. Each off-set can be adjusted within a range of from -10 to +10.
After running the refrigeration system for a few hours, place a digital thermometer (not supplied) inside the
compartment, in a location where a more accurate temperature is required, and check that the temperature
shown on the display coincides with the temperature shown on the digital thermometer. If the temperature
is not the same, the off-sets must be adjusted in relation to the temperature T you want the inside of the
compartment to reach, so that the temperature reading on the display coincides with the temperature
indicated by the thermometer.
The following table shows the factory off-set setting for each temperature range and the adjustment range
for changing these settings.
OFF-SET
Temperature Range
F1
F2
F3
With the refrigerator switched off, press and hold the SET +  +  buttons at the same time for a few
seconds to access the OFF-SET value adjustment.
Press the  and  buttons number of times to scroll through the three functions (F1-F2-F3) in succession.
Once you have selected the function you wish to change, press the SET button to access the selected
OFF-SET value and press the  and  buttons to change the factory setting, while remaining within the
+10°C ÷ -10°C range. Without having to press any other button to confirm, the display will automatically
save the setting and exit programming mode.
TB15-18_new 2017_05-09-2017
T ≥ -6°C
-12°C ≤ T ≤ -6°C
T ≤ -13°C
Factory setting
-2°C
-4°C
-4°C
ENGLISH
Adjustment range
+10°C ÷ -10°C
+10°C ÷ -10°C
+10°C ÷ -10°C