Descargar Imprimir esta página

Filter And Facepieces; Breathing Hoses; Carrying Systems; Rechargeable Batteries - Dräger X-ploreb8000 Instrucciones De Uso

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
Illustration of fan unit rear on the fold-out page (Figure C)
1 Carrying system socket
2 Name plate
3 Carrying system lock button
4 Battery lock button
5 Rechargeable battery (not enclosed with fan unit)
Control panel
Illustration on the fold-out page (Figure D)
1 Rechargeable battery status indicator
2 Residual particle filter capacity indicator
3 On/off button
4 Flow rate indicator
5 Reduce flow rate
6 Increase flow rate
Explanation of control panel indicators
Indicator
Explanation
Battery capacity depending on number
of displayed segments:
Segments light up
in green.
> 75 % (4 segments)
> 50 % (3 segments)
> 25 % (2 segments)
< 25 % (1 segment)
Residual capacity of particle filter
pending on number of displayed seg-
Segments light up
ments:
in green.
> 75 % (4 segments)
> 50 % (3 segments)
> 25 % (2 segments)
< 25 % (1 segment)
Flow rate intensity depending on num-
ber of displayed segments:
high flow rate (3 segments)
Segments light up
medium flow rate (2 segments)
in green.
low flow rate (1 segment)
1) The residual capacity of the gas filter or the gas filter components
of the combination filter cannot be indicated.
NOTICE
i
i
Warnings or alarms are indicated by flashing yellow or
red LEDs. For an explanation of malfunction indica-
tors, see section 4 on page 20.
2.2.2

Filter and facepieces

Filter and facepieces are described in separate Instructions for
Use.
2.2.3

Breathing hoses

The following breathing hoses are available:
standard hose
flexible hose for increased comfort
Both breathing hoses are available for each of the following fa-
cepiece types:
plug-in connector (hood)
Dräger X-plore 8000
bayonet-type connector (helmet and protective visor)
round-thread connector (half/full face mask)
2.2.4

Carrying systems

Illustration on the fold-out page (Figure E)
1 Connection plate
2 Webbing
3 Clips on ends of the belt
4 Buckle
The following carrying systems are available:
Standard belt
The standard belt consists of a textile webbing and press
studs to attach comfortable padding.
Decontaminable belt:
The decontaminable belt has a smooth plastic webbing
and is particularly recommended for decontamination.
2.2.5

Rechargeable batteries

Illustration on the fold-out page (Figure F)
1 Battery lock button
2 Battery status indicator
3 Button to display battery capacity
4 Name plate
The rechargeable Li-ion batteries are specially designed for
1)
de-
use with the powered air purifying respirator. A long-life re-
chargeable battery is also available in addition to the standard
rechargeable battery.
The battery status indicator shows the battery capacity while
you charge the unit with the standard charger or when you
push the button. The segments of the battery status indicator
are flashing while you charge the unit.
The battery status indicator corresponds to that on the control
panel of the fan unit (see section 2.2.1 on page 16).
The rechargeable batteries reach their full capacity after 5
charge and discharge cycles. The standard charge takes ap-
prox. 3 hours.
In cases where the battery has been completely drained
charging may take up to 4 hours longer. During this time the
battery status indicator is not supported.
To prevent damage to or explosion of the rechargeable battery,
charging is limited to a temperature range of 0 to 50 °C. If this
temperature range is exceeded or falls below, charging will
stop automatically and continue once the temperature range is
reached again.
2.2.6

Battery chargers

Standard battery charger
Illustration on the fold-out page (Figure G)
1 Status LED
2 Power supply unit
3 Battery compartment
Description
17

Publicidad

Solución de problemas

loading