Dynamic Weighing - Steinberg Systems SBS-KW-1000/10G Manual De Instrucciones

Ocultar thumbs Ver también para SBS-KW-1000/10G:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
ZERO RANGE
Zero Range defines the range that scale must fall into before activating the accu¬mulation operation. When
the load is removed from the scale, the weight left must be lighter than the value set.
Press
, to enter the Zero range setting.
Press
to change the value. Press and hold
Range value. Press and hold
to set the decimal point. Zero Range can be set from 0e to 3000e. It is set
to „5e" by deafult.
ZERO-SAVING
When Zero-saving is enabled, Auto Zero is disabled automatically. Scale calcu¬lates weight based on the last
Zeroing action. It is disabled by default.
Press
, to enter Zero Saving.
Press
, to change the status to „on" (enabled) or „off" (disabled).
ANTI-MOTION
At the cost of measuring time, the Anti-Motion function intelligently settles the determination of weight
when the scale is in motion. The weaker Anti-Motion is, the faster the scale displays the weight, but the longer
EN
it takes to be stable.
Anti-Motion can be set to: 0 (off), 1 (weakest), 2 (weak), 3 (normal), 4 (strong), 5 (strongest).
Press
, to enter the Anti-motion setting.
Press
to change the value.

DYNAMIC WEIGHING

In some special application where the scale´s accuracy is not so important as the scale´s stability for the
weight reading, the dynamic weighing can be a useful function to set the weight reading faster.
Press
, to enter the Dynamic Weighing setting.
shows.
Press
, to change the status to „on" (enabled) or „off" (disabled).
REV. V 2016
shows.
to move the digit. Input the Zero
shows.
shows.
22
GRAVITY
Scale shows active value, e.g. G9.794 for g = 9,794. Only adjust the Gravity when the scale is used in a place
where the acceleration of gravity is greatly different from the place where it was calibrated.
Press
, to enter the Gravity setting. G---- shows.
Press
, to modify the digit. Press and hold
Press and hold
to input the decimal point.
USER UNIT
The User Unit can be set from 0.000 to 9.999.
The User Unit is a named unit which is usually used in the user's region, but which is not included in the scale
by default. It is a ratio to the System Unit. For example, if the User Unit is set to 1.234 and if the System Unit
is kg, then after switching to User Unit, the scale measures the weight (1000kg), and displays the calculated
value (1234usr).
This means you have to watch up the maximal load hanging on the scale while using the user unit, to not
overload the scale because of a different displayed value!
Press
, to enter the User Unit setting. U ---- shows.
Press
, to modify the digit. Press and hold
value. Press and hold
to input the decimal point.
CALIBRATION
ENTERING CALIBRATION SETTINGS
Simultaneously press
,
and
, to enter the Password mode.
The scale displays P0000. Press
, to modify the digits. Press and hold
the Calibration password: P8416.
Press
länger gedrückt, um den Cursor zu bewegen. Geben Sie das Kalibrierungspasswort (P8416) ein.
Drücken Sie
, to confirm the input and to enter Calibration. CAL shows.
SYSTEM UNIT
The Scale displays the System Unit. The System Unit can be set to: kg and lb.
Press
, to enter the System Unit setting. Un--- shows.
Press
, to change the System Unit.
REV. V 2016
to move the digit. Input the Gravity value.
to move the digit. Input the User Unit
to move the digit. Input
23
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

10030128

Tabla de contenido