The PC board activates the water drain pump for 20 seconds,
pumping out most of the water contained in the water reservoir.
The water can be pumped out up a rise of to 1.5m (59") or
over a on horizontal length of 1.5m (59").
If water level switch 2 closes, transmitting a low-voltage
current to the PC board, the PC board activates the buzzer
alarm, informing you that the drain pump, water level
switch or drain tube may be malfunctioning.

Schematic Diagram

19
NOTE:
The outlet of the drain hose
must be raised higher than the
water surface to prevent the
drained water from flowing
back into the water reservoir.
WARNING!
If alarm buzzer sounds, turn
off the ice maker and the
water supply, remove all ice
from storage bin, and wipe up
any water that may have
overflowed. Check if there is
any water in water trough at
back of unit; if no water,
drainage pump may not be
receiving the proper amount
of
power.
Check
source. If the problem can be
corrected, turn on the unit
again. Also check that none
of the water lines are kinked.
If
the
problem
contact SUMMIT Customer
Service.
power
remains,