To prevent unnecessary expense, we recommend that you always first carefully
consult the instructions for use. Take the air conditioner to your dealer for repairs
if these instructions do not provide a solution.
L
TECHNICAL DATA
To be used as indication, subject to modifications
Model
Cooling capacity *
- enthalpy difference (nom)
- enthalpy difference
- conform EC regulation
Power consumption
Current nom.
Mains (1PH)
Air delivery max.
Dehumidification max. **
Room size
Compressor model
Refrigerant
Thermostat range
Fan speeds
Noise level indoor unit
Noise level outdoor unit
Length flexible tube
Dimensions indoor unit (b x d x h)
Dimensions outdoor unit (b x d x h)
Weight indoor unit
Weight outdoor unit
Unit protection indoor unit
Unit protection outdoor unit
*
Cooling capacities are measured at 27°C, 60% RH
** Moisture removal at 32°C, 80% RH
PX150
Btu/hr
14000
kW
4.1
W
3000
W
1180
A
5.3
V / Hz
220-240 / 50
430
m
3
/h
L/24h
33
100
3
m
rotary
gr
R407C / 670
°C
16 - 30
2
dB
52-58
dB
< 64
mm
300
mm
380x400x750
mm
450x240x580
kg
29
kg
12
IP20
IP24
4